Derek David, SimplexGrinnell Who is responsible for the inspection, testing and maintenance of the fire alarm system? The building does not have an automatic sprinkler system. Managing the fireground risk begins with the code hearings an Each system is intended to meet specific needs. Listing of references allowed in testing centers and some books that might be useful in preparing for an exam. Chris J. Barrera Sr., ECSI A charger test of a lead-acid battery with a voltmeter shall confirm that the voltage per cell is __________ volts at ___________ degrees F. What type of training/ cert is intended to allow individuals to service a specific brand of fire alarm equipment for which they have been trained? The system owner of their designated representative. True or False, When testing a releasing system the solenoid must remain connected for the duration of the fire system test. R During Scheduled shutdowns approved by AHJ. For more information on rescheduling, click here. Title Page - Edit and print this page with the information about the reference, according to the standard. A record of any fire system Impairment shall be kept by the ___________ for a period of 1 year from the date that the impairment is__________. The ceiling is 10 feet high and level. Just follow the same process as detailed above. Candidates who are testing using the online remote proctored (ONVUE) option may rescheduling their appointment date/time right up until their appointment without incurring additional fees. To avoid over pressurizing the system. What are the fire alarm initiation requirements for this occupancy? When testing a water level supervisory switch serving a pressurized water storage tank, a signal must be indicated whenever the water_______ from the normal level. how often must manual fire alarm boxes be tested? The battery must be recharged in____________. Level II The control unit shall identify the affected detector when the compensation limit has been reached. Tom Parrish, Telgian Corporation Water is flowing thru it properly, Pressure readings for a water . Put the meter in series with the circuit (Pulling negative wire and replacing it with voltmeter to read current). Level II Monitoring for integrity is not required for the circuit of an alarm notification appliance installed __________ . Fire Alarms Online | NICET Practice Tests and Answers What is the required test frequency for a pressure-type water flow initiating device? All fire alarm service personnel shall be qualified and ___________. Sample NICET Inspection & Testing of Fire Alarm Systems Practice Test Welcome to the NICET Inspection & Testing of Fire Alarm Systems Sample Test! Contact Us. Verify that the installed system meets the operation requirements of the version of code when the system was installed, verify the correct operation of the system. Correct answers will usually be selected by clicking the boxes next to the answers. Smoke detectors may be installed during construction, but not operational, as long as they are protected from debris, dust, dirt, and similar contamination. Applicants with a disability as defined in Title III of the Americans with Disabilities Act who may be placed at a disadvantage when taking a NICET certification examination may request a testing accommodation by contacting [email protected] prior to scheduling testing. The exam will be administered on a computer at a proctored test center managed by a test administration company. The manufactures published instructions and NFPA 72. NICET uses a scaled score for consistency across all exams. Failure to accept will result in a failed score and fees will be forfeited. Certification requirements for each Level build on those of lower Levels: Certification at Levels II or III does not require prior certification at the lower level, but it does require that the certification requirements of the lower levels have been met. Which section of the contract documents typically contain fire alarm system requirements? Welcome to the NICET Inspection & Testing of Water-Based Systems Sample Test! According to the Nicet test, when should a tourniquet be applied to a bleeding wound? To ensure public mode signals are clearly heard, they shall have a sound level of at least _______ db above the average ambient sound level? The National Institute for Certification in Engineering Technologies (NICET) has partnered with Pearson VUE to deliver the computer-based certification examinations. Craig Peterson, 3D Security, Inc. EMERGENCY VOICE EVACUATION SYSTEMS SHALL HAVE SUFFICIENTBATTERY BACK-UP TO OPERATE THE SYSTEM FOR ______ HOURS OF STAND-BY AND _____ MINUTES OF ALARM. Level I Contact Us, Inspection and Testing of Fire Alarm Systems, Development Volunteers and the Companies that Supported Their Participation. What is the required test method for nonrestorable heat detectors? Donald Laningham, Siemens Inc A manual fire alarm system. What are the colors and corresponding number codes of a resistor? IBC 907.2.7, pg 218. Technical areas covered include types of fire alarm systems and their respective components, device and circuit specific test procedures for initiating devices, notification appliances, supervisory signal-initiating devices, primary and secondary power supplies, emergency communications equipment, interface with other systems, and on/off premises monitoring. All styles of class A circuits using physical conductors shall be installed such that the outgoing and return conductors, exiting from and returning to the control unit, respectively, are ______________. Then click the exam name to view the appointment then "Reschedule" on the right side of the screen. Failure to accept will result in a failed score and fees will be forfeited. How often are fire alarm devices to be cleaned? When testing and inspecting backup power systems, at what interval should lead acid batteries be replaced? How often shall secondary power supply be tested? One group of doors leaving an office building measures 40 feet in width. *This exam contains a 30-minute break. NICET Inspection and Testing of Fire Alarm Systems Certification - Level I. Computer-based testing (CBT) allows NICET to extend several benefits to our customers: more flexible exam dates and appointment times; immediate scheduling and confirmation; and quicker exam scoring. You can purchase the Fire Alarms Online NICET Practice Test to the left via the secure PayPal checkout. I am now NICET 2 certified. John Horn, Tyco Industries Mar. Kip Strobel, CH2MHILL Engineers Inc. Learn how to build the best ground fault meter with step by step instructions. A). I understand that NICET tests and test questions are owned and copyrighted by NICET and affirm that I will not share the content of any NICET examination with any other person. These exams are normally closed book; any exception to this policy will be stated in the test information for that program. The corridor is 10' wide and 120' long. The owners of monitored fire alarm systems must provide to the local AHJ documents identifying _______________. What is the minimum number of smoke detectors in the corridor. [A>k4ELh7pAy`9: `uJh3i_. Please contact PearsonVUE. ! Applicants with a disability as defined in Title III of the Americans with Disabilities Act who may be placed at a disadvantage when taking a NICET certification examination may request a testing accommodation by contacting [email protected] prior to scheduling testing. Eric H. Ricker, SimplexGrinnell Steve Tiner, Adcock Systems Personnel who are certified by a nationally recognized fire alarm certification organization acceptable to the AHJ. The circuit disconnect means (breaker) for a fire alarm system to the power source shall _____________. A ANY ACTIVATED DETECTOR WOULD CAUSE AN ALARM. Consider a room which is 40' square. Rich Castle, Electronic Systems International, Inc. You must specify a text. George Sharer, Fire Engineering Services What type of cable is required for this if the cable will not be installed in a metal raceway or fireproof shaft? The #1 website for NICET Practice Tests, NICET study guides, Fire Alarm Code Knowledge, and General Fire Alarm Topics. In a few questions, you may be presented a picture and asked to click on the part of the picture that correctly answers the question. General areas covered include inspection and testing procedures, periodicity, documentation, safety, and work management. in the same room with the central control equipment. Any unused time will NOT extend the time allotted for answering exam questions. Each request will be evaluated individually and every effort will be made to offer reasonable accommodations to qualifying applicants. After the final acceptance test, how is the owner given the software programing for his system? The process is not complete until you click the Confirm Reschedule button, see the notice: Your Appointment is Rescheduled and receive a confirmation email. For more information on rescheduling, click here. HOW MANY CONDUITS CAN BE CONNECTED TO ONE SEISMICWIRE? Scott Bailey, Tyco Integrated Security Solid practice tests for the NICET exam will make it easy to understand where to locate the answers or in some case if the answers are not in a reference, the test should break down the solution in an easy to understand manner. Scores below 200 are reported as 200; scores of 500 or above are reported as "Pass." Score Report The document that describes how a candidate performed on the exam. Applicants are presented with the option to select online administration through OnVue during the scheduling step. Again, thanks for the class and the study material that was provided. Tommy Farr, JATC of Southern Nevada What are the fire alarm initiation requirements for this occupancy? You may also call Pearson VUE at 1-866-880-0048 to reschedule. The Inspection and Testing of Water-Based Systems certification program is for engineering technicians engaged in the inspection and testing of existing water-based fire protection systems, including identifying and addressing emergency and pre-planned impairments. 0306-1109. Title Page - Edit and print this page with the information about the reference, according to the standard. Home - NICET Please contact PearsonVUE. NFPA 72 states that all fire alarms shall test free of ________. An automatic smoke detection system shall be installed in corridors and spaces permitted to be open to corridors. McKay (Luke) Baird, Walmart WHICH TYPE OF DETECTOR IS AFFECTED BY ALTITUDESOVER 3000? 90 days access to Level 1-4 NICET Fire Alarm Certification Online Training. Are all supplemental circuits required to be monitored for integrity? Certification Requirements - NICET How frequently are rate-compensated heat detectors to be tested? An open ground or short-circuit fault on the installation conductors of one _________ is not permitted by NFPA 72 to affect the operation of_________. Candidates who are testing using the online remote proctored (ONVUE) option may rescheduling their appointment date/time right up until their appointment without incurring additional fees. NTC develops and conducts training for NICET Certification, Continuing Education and career development. Jon Pomerantz, Universal Surveillance Systems (USS) When the appliances are within the same notification zone. Which class of signalling Line circuit is required to provide operational capability during a single open, single ground, or wire to wire shirt abnormal condition as well as a combined open & Ground? Then click the exam name to view the appointment then Reschedule on the right side of the screen. The Inspection and Testing of Water-Based Systems exam is delivered on a computer at Pearson Vue Testing Centers. Bradley Wilcox, SET, CFPS, GHD Electrically test and mechanically activate. How often are video image smoke and fire detectors required to be inspected? Unless in conduit, conductors of class 2 and class 3 circuits shall be separated by at least __________ from conductors of any electric light, power, class 1 or non power -limited fire alarm circuits. , learning the proper way to navigate the referencessuch as NFPA 72 (2013) and NEC or NFPA 70 (2011). On the inspection record you must now________. This certification program was designed for engineering technicians working in the fire alarm industry who engage in a combination of the following fire alarm systems activities: system layout (plan preparation), system equipment selection, system installation, system acceptance testing, system trouble-shooting, system servicing, and system technical sales. You must specify an email address. IBC 907.2.6.2, pg 217. Within 24 hours, after your scheduled date or for a new testing window there is an additional fee equal to one half of the original testing fee. This building would require _______ sleeping accommodations with visible alarm notification? Candidates may not bring any additional calculators into the testing room. A ____________ is defined as a visual evaluation of fire system components performed to verify or confirm that something appears as desired? The archiving of all required test inspection records _____________ shall be permitted if a written copy of these records can be provided promptly, when requested? Monitoring for integrity of a circuit is not required if a single open or ground fault causes an alarm signal. Activation of the fire alarm in a Group A occupancies with an occupant load of ______ or more shall initiate a signal using an emergency voice/alarm communication system?